Renovation of a house in Saint-Gilles in an urban environment. Project submitted to the competition BATEX (Exemplary buildings).
After a geological survey and design of the geothermal system, placement of 2 probes, one vertical and one sloping passing below the house to optimise the available space. Total length of the probes: 140 metres.
Features :
- Setting up of a crane to pass over the houses and reach the small garden.
- Carrying out of a Thermal Response Test (TRT). The TRT report confirmed the expected sizing and highlighted the extremely low thermal resistivity of the geothermal system, partly due to the quality of the stainless steel probes used.
Demolition - rebuilding of a notary's office in Bastogne in an urban environment.
A geological survey and sizing of the geothermal system in close collaboration with the consultancy firm ECORCE which carried out the thermal survey and works supervised by the architect David. Placement of 2 vertical probes, each to a depth of 90 metres..
Features : heating and air conditioning through geocooling.
Construction of a new industrial building for the butcher Renmans in Rhisnes.
A geological survey and sizing of the geothermal system in close collaboration with the consultancy firm Bsolutions which carried out the thermal survey. Placement of six 90 metre vertical probes.
Construction of a new building for a school in Neder-Over-Heembeek for the City of Brussels.
A geological survey and sizing of the geothermal system in close collaboration with the consultancy firm ECORCE which carried out the thermal survey. Placement of 4 probes and 4 sloping probes, 2 by 2, for a total of 560 metres.